- E3O1 ObjectiveThe Objective of this Part is to— facilitate the safe movement of occupants; and facilitate access for emergency services personnel to carry out…
- E3F1 Passenger liftsWhere a passenger lift is provided, it is to facilitate safe and easy— movement for occupants with a disability; and evacuation of occupants, who…
- E3F2 Emergency liftsA building is to be provided with one or more passenger lifts to facilitate— the safe access for emergency services personnel; and safe and easy…
- E3F3 Emergency alertsA building having a passenger lift is to be provided with measures to alert occupants about the use of the lift in an emergency.
- E3P1 Stretcher facilitiesStretcher facilities must be provided, to the degree necessary— in at least one emergency lift required by E3P2; or where an emergency lift is not…
- E3P2 Emergency liftsOne or more passenger lifts fitted as emergency lifts to serve each floor served by the lifts in a building must be installed to facilitate the…
- E3P3 Emergency alertsSigns or other means must be provided to alert occupants about the use of a lift during an emergency.
- E3P4 Lift access for people with a disabilityWhen a passenger lift is provided in a building required to be accessible, it must be suitable for use by people with a disability.
- E3V1 Fire Safety Verification MethodCompliance with E3P2 is verified when a building is designed in accordance with C1V4.
- E3V2 Emergency alerts on the use of liftsCompliance with E3P3 is verified when building occupants are provided with automatic warning that lifts must not be used during a fire emergency.…
- E3D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements E3P1 to E3P4 are satisfied by complying with— E3D2 to E3D12; and for a…
- E3D2 Lift installationsAn electric passenger lift installation and an electrohydraulic passenger lift installation must comply with Specification 24.
- E3D3 Stretcher facility in liftsA stretcher facility in accordance with (2) must be provided— in at least one emergency lift required by E3D5; or where an emergency lift is not…
- E3D4 Warning against use of lifts in fireA warning sign must be displayed where it can be readily seen near every call button for a passenger lift or group of lifts throughout a building.…
- Table E3D5 Minimum emergency lift dimensions in Class 9a buildingsLift component | Minimum dimension (mm) Minimum depth of car | 2280 Minimum width of car | 1600 Minimum floor to ceiling height | 2300 Minimum door…
- E3D5 Emergency liftsAt least one emergency lift complying with (4) must be installed in— a building which has an effective height of more than 25 m; and a Class 9a…
- E3D6 LandingsAccess and egress to and from lift well landings must comply with Parts D2, D3 and D4.
- E3D7 Passenger lift types and their limitationsIn an accessible building, every passenger lift must be one of the following lift types, subject to the limitations (if any) of each lift type:…
- E3D8 Accessible features required for passenger liftsIn an accessible building, every passenger lift must have the following features where applicable: A handrail complying with the provisions for a…
- E3D9 Fire service controlsWhere lifts serve any storey above an effective height of 12 m, the following must be provided: A fire service recall control switch complying with…
- E3D10 Residential care buildingsWhere residents in a Class 9c residential care building are on levels which do not have direct access to a road or open space, the building must be…
- E3D11 Fire service recall control switchEach group of lifts must be provided with one fire service recall control switch required by E3D9 that activates the fire service recall operation…
- E3D12 Lift car fire service drive control switchThe lift car fire service drive control switch required by E3D9 must be activated from within the lift car. (2) The switch must— be located between…