Deemed-to-Satisfy Provision · NCC 2022 Volume One

F1D5 External waterproofing membranes

Part F1 Surface water management, rising damp and external waterproofing · NCC 2019: F1.4

Open F1D5 on NCC Online ↗

A roof, balcony, podium or similar horizontal surface part of a building must be provided with a waterproofing membrane—

consisting of materials complying with AS 4654.1; and

designed and installed in accordance with AS 4654.2.

Changed in NCC 2025. See NCC 2025 Volume One F1D5, or show what changed.

A (1) In a building or part of a building, where a roof, balcony, podium podium, or similar horizontal surface part of a building is constructed of concrete, it must comply with AS 3600. (2) The surface of structural substrates in (1) must be provided with a waterproofing membrane — consisting of materials complying with AS 4654.1; and designed and installed prepared in accordance with AS 4654.2. F1D7(1)(b) to be suitable for application of a membrane.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Can't meet F1D5? A Performance Solution must meet the Performance Requirements it satisfies: F1P1, F1P2, F1P3, F1P4. Start a Performance Solution →

Defined terms used