Deemed-to-Satisfy Provision · NCC 2022 Volume One

F6D6 Ventilation of rooms

Part F6 Light and ventilation · NCC 2019: NSW F4.5(b), SA F4.5(b) and (c), F4.5

Open F6D6 on NCC Online ↗
Varied in NSW, SA. Check the variation for your state.

A habitable room, office, shop, factory, workroom, sanitary compartment, bathroom, shower room, laundry and any other room occupied by a person for any purpose must have—

natural ventilation complying with F6D7; or

a mechanical ventilation or air-conditioning system complying with AS 1668.2 and AS/NZS 3666.1.

Changed in NCC 2025. See NCC 2025 Volume One F6D6, or show what changed.

A habitable room, office, shop, factory, workroom, sanitary compartment, bathroom, shower room, laundry and any other room or space occupied by a person for any purpose must have — natural ventilation complying with — F6D7; or AS 1668.4; or a mechanical ventilation or air-conditioning system complying with AS 1668.2 and AS/NZS 3666.1.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Can't meet F6D6? A Performance Solution must meet the Performance Requirements it satisfies: F6P1, F6P2, F6P3, F6P4, F6P5. Start a Performance Solution →

State and territory variations all clauses side by side →