New South Wales variation · NCC 2022 Volume One

NSW F6D6 Ventilation of rooms

Part F6 Light and ventilation · varies F6D6 Ventilation of rooms

Open on NCC Online ↗

Delete clause F6D6 and insert NSW F6D6 as follows:

A habitable room, office, shop, factory, workroom, sanitary compartment, bathroom, shower room, laundry and any other room occupied by a person for any purpose must have—

natural ventilation complying with F6D7; or

a mechanical ventilation or air-conditioning system complying with AS 1668.2.

Notes

The reference to AS/NZS 3666.1 is deleted from the BCA in NSW, as the need to comply with this standard is regulated in the Public Health Regulation 2012, under the Public Health Act 2010.

Changed in NCC 2025. See NCC 2025 Volume One NSW F6D6, or show what changed.

Delete clause F6D6 and insert NSW F6D6 as follows: A … sanitary compartment, bathroom, shower room, laundry and any other room or space occupied by a person for any purpose must have — natural ventilation complying with — F6D7; or AS 1668.4; or a mechanical ventilation or air-conditioning system complying with AS … with this standard is regulated in the Public Health Regulation 2012, 2022, under the Public Health Act 2010.

Removed words are struck through; added words are highlighted. Comparison of the text only.

The national clause

Other states and territories