NSW I1D1 Application of Part
Part I1 Class 9b buildings · varies I1D1 Application of Part
Delete clause I1D1 and insert NSW I1D1 as follows:
(1) For a Class 9b building or part of a building that is not an entertainment venue—
the Deemed-to-Satisfy Provisions of Part I1 apply to every enclosed Class 9b building or part of a building which—
is a school assembly, church or community hall with a stage and any backstage area with a total floor area of more than 300 m2; or
otherwise, has a stage and any backstage area with a total floor area of more than 200 m2; or
has a stage with an associated rigging loft; and
notwithstanding (1)(a)—
I1D4 applies to every open or enclosed Class 9b building; and
I1D7 applies to every enclosed Class 9b building.
(2) For a Class 9b building that is an entertainment venue, NSW Part I4 applies in replacement of Part I1.