Part F8 Condensation management
10 clauses · Open on NCC Online ↗
- F8O1 ObjectiveThe Objective of this Part is to safeguard occupants from illness or loss of amenity as a result of excessive internal moisture. Applications F8O1…
- F8F1 CondensationA building is to be constructed to avoid the likelihood of excessive internal moisture accumulating within the building structure. Applications F8F1…
- F8P1 Condensation and water vapour management TASRisks associated with water vapour and condensation must be managed to minimise their impact on the health of occupants. Applications F8P1 only…
- F8V1 Condensation managementCompliance with Performance Requirement F8P1 is verified for a roof or external wall assembly when it is determined that a mould index of greater…
- F8D1 Deemed-to-Satisfy ProvisionsCompliance with Performance Requirement F8P1 is satisfied by complying with Deemed-to-Satisfy Provisions F8D2 to F8D5. (2) Where a Performance…
- F8D2 Application of PartThe Deemed-to-Satisfy Provisions of this Part only apply to a sole-occupancy unit of a Class 2 building and a Class 4 part of a building.
- F8D3 External wall constructionWhere a pliable building membrane is installed in an external wall, it must— comply with AS 4200.1; and be installed in accordance with AS 4200.2;…
- F8D4 Exhaust systemsAn exhaust system installed in a kitchen, bathroom, sanitary compartment or laundry must have a minimum flow rate of— 25 L/s for a bathroom or…
- Table F8D5 Roof space ventilation requirementsRoof pitch | Ventilation openings <10° | 25,000 mm2/m provided at each of two opposing ends ≥10° and <15° | 25,000 mm2/m provided at the eaves and…
- F8D5 Ventilation of roof spacesIn climate zones 6, 7 and 8, a roof must have a roof space that— is located— immediately above the primary insulation layer; or immediately above…