South Australia variation · NCC 2022 Volume One

SA C2D2 Type of construction required

Part C2 Fire resistance and stability · varies C2D2 Type of construction required

Open on NCC Online ↗

Delete subclause C2D2(1) and insert SA C2D2(1) as follows:

(1) The minimum Type of fire-resisting construction of a building must be determined in accordance with Table C2D2, except as allowed for—

certain Class 2, 3 or 9c buildings, in C2D6; and

a Class 4 part of a building located on the top storey, in C2D4(2); and

open spectator stands and indoor sports stadiums, in C2D8; and

Class 2 buildings located within 3 m of a brush fence and Class 10b brush fences located within 3 m of a Class 2 building, in SA C2D2(3) and (4); and

a Class 7b bulk grain storage facility in SA C2D16.

Insert SA subclause C2D2(3) in clause C2D2 as follows:

(3) In addition to the minimum fire-resisting construction requirements of Table C2D2 and Specification 5 a Class 2 building must not be constructed within 3 m of a Class 10b brush fence unless any part of the building within 3 m of the brush fence complies with the fire-resisting requirements of SA C2D16.

Insert SA subclause C2D2(4) in clause C2D2 as follows:

(4) A Class 10b brush fence must not be constructed within 3 m of a Class 2 building unless any part of the building within 3 m of the brush fence complies with the fire-resisting construction requirements of SA C3D16.

Changed in NCC 2025. See NCC 2025 Volume One SA C2D2, or show what changed.

Delete subclause C2D2(1) and insert SA C2D2(1) as follows: (1) … m of a Class 2 building, in SA C2D2(3) and (4); and a Class 7b bulk grain storage facility in SA C2D16. (4). Insert SA subclause C2D2(3) in clause C2D2 as follows: (3) … the brush fence complies with the fire-resisting requirements of SA C2D16. C3D16. Insert SA subclause C2D2(4) in clause C2D2 as follows: (4) … fence complies with the fire-resisting construction requirements of SA C3D16.

Removed words are struck through; added words are highlighted. Comparison of the text only.

The national clause