Table · NCC 2022 Volume One

Table J3D7r Timber-framed flat, skillion or cathedral roof — minimum R-Value for ceiling insulation: climate zones 7 and 8

Part J3 Elemental provisions for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Open Table J3D7r on NCC Online ↗
Reflective insulation under-roofSA ≤ 0.23SA > 0.23 to ≤ 0.32SA > 0.32 to ≤ 0.42SA > 0.42 to ≤ 0.53SA > 0.53 to ≤ 0.64SA > 0.64 to ≤ 0.73SA > 0.73 to ≤ 0.85SA > 0.85
Yes4.54.54.54.04.04.04.04.0
No5.04.54.54.04.03.53.53.5

Table Notes

SA = solar absorptance.

The R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.

The R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.

R-Values listed are for the labelled, declared R-Value for insulation.

Table for J3D7 Roofs and ceilings of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table J3D7r.

Defined terms used