Table · NCC 2022 Volume One

Table J4D6a Minimum wall Total R-Value - Wall area 80% or more of wall-glazing construction area

Part J4 Building fabric

Open Table J4D6a on NCC Online ↗
Climate zoneClass 2 common area, Class 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward areaClass 3 or 9c building or Class 9a ward area
12.43.3
21.41.4
31.43.3
41.42.8
51.41.4
61.42.8
71.42.8
81.43.8

Table for J4D6 Walls and glazing

Changed in NCC 2025. See NCC 2025 Volume One Table J4D6a, or show what changed.

Climate zone | Class 2 common area, Class 5, 6, 7, 8 or 8, 9b building or a Class 9a building other than a ward area | Class 3 or 9c building or a Class 9a ward area 1 | 2.4 1.6 | 3.3 1.1 2 | 1.4 1.9 | 1.4 1.6 3 | 1.4 1.7 | 3.3 1.2 4 | 1.4 1.7 | 2.8 1.3 5 | 1.4 1.9 | 1.4 1.6 6 | 1.4 1.8 | 2.8 1.6 7 | 1.4 1.7 | 2.8 1.2 8 | 1.4 2.0 | 3.8 1.1

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used