Table · NCC 2025 Volume One

Table J4D6a Maximum Total System U-Value of wall-glazing construction

Part J4 Building fabric

Open Table J4D6a on NCC Online ↗
Climate zoneClass 5, 6, 7, 8, 9b building or a Class 9a building other than a ward areaClass 3 or 9c building or a Class 9a ward area
11.61.1
21.91.6
31.71.2
41.71.3
51.91.6
61.81.6
71.71.2
82.01.1

Table for J4D6 Walls and glazing

Changed since NCC 2022. See NCC 2022 Volume One Table J4D6a, or show what changed.

Climate zone | Class 2 common area, Class 5, 6, 7, 8 or 8, 9b building or a Class 9a building other than a ward area | Class 3 or 9c building or a Class 9a ward area 1 | 2.4 1.6 | 3.3 1.1 2 | 1.4 1.9 | 1.4 1.6 3 | 1.4 1.7 | 3.3 1.2 4 | 1.4 1.7 | 2.8 1.3 5 | 1.4 1.9 | 1.4 1.6 6 | 1.4 1.8 | 2.8 1.6 7 | 1.4 1.7 | 2.8 1.2 8 | 1.4 2.0 | 3.8 1.1

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used