Table · NCC 2025 Volume One
Table J4D6a Maximum Total System U-Value of wall-glazing construction
| Climate zone | Class 5, 6, 7, 8, 9b building or a Class 9a building other than a ward area | Class 3 or 9c building or a Class 9a ward area |
|---|---|---|
| 1 | 1.6 | 1.1 |
| 2 | 1.9 | 1.6 |
| 3 | 1.7 | 1.2 |
| 4 | 1.7 | 1.3 |
| 5 | 1.9 | 1.6 |
| 6 | 1.8 | 1.6 |
| 7 | 1.7 | 1.2 |
| 8 | 2.0 | 1.1 |
Table for J4D6 Walls and glazing
Changed since NCC 2022. See NCC 2022 Volume One Table J4D6a, or show what changed.
Climate zone | Class 2 common area, Class 5, 6, 7, 8 or 8, 9b building or a Class 9a building other than a ward area | Class 3 or 9c building or a Class 9a ward area 1 | 2.4 1.6 | 3.3 1.1 2 | 1.4 1.9 | 1.4 1.6 3 | 1.4 1.7 | 3.3 1.2 4 | 1.4 1.7 | 2.8 1.3 5 | 1.4 1.9 | 1.4 1.6 6 | 1.4 1.8 | 2.8 1.6 7 | 1.4 1.7 | 2.8 1.2 8 | 1.4 2.0 | 3.8 1.1
Removed words are struck through; added words are highlighted. Comparison of the text only.