Victoria variation · NCC 2022 Volume One

VIC G5P2 Additional bushfire requirements for certain Class 9 buildings

Part G5 Construction in bushfire prone areas · varies G5P2 Additional bushfire requirements for certain Class 9 buildings

Open on NCC Online ↗

Delete clause G5P2 and insert VIC G5P2 as follows:

A building that is constructed in a designated bushfire prone area and occupied by people who may be unable to readily evacuate the building prior to a bushfire must, to the degree necessary—

reduce the risk of an untenable indoor environment for occupants during a bushfire event, appropriate to the—

location of the building relative to fire hazards, including—

classified vegetation; and

adjacent buildings, structures and movable objects; and

carparking areas and allotment boundaries; and

other combustible materials; and

number of occupants to be accommodated within the building; and

intensity of bushfire attack on the building; and

duration of occupancy; and

intensity of potential consequential fires; and

occupant tenability within the building before, during and after the bushfire event; and

combined effects of structural, fire exposure and other effects to which the building may reasonably be subjected; and

provision of fire fighting equipment and water supply to facilitate protection of the building; and

be provided with vehicular access to the site to enable firefighting and emergency personnel to defend or evacuate the building; and

have access to a sufficient supply of water for firefighting purposes on the site; and

provide safe access within the site to the building (including carparking areas), as well as safe egress after the bushfire event.

Applications

VIC G5P2 applies to the following buildings located in a designated bushfire prone area—

a Class 9a health-care building; and

a Class 9b—

early childhood centre; and

primary or secondary school; and

a Class 9c residential care building; and

a Class 4 part of a building associated with a building of a type listed in (a) to (c).

Notes

VIC G5P2 does not guarantee the safety of building occupants or the maintenance of tenable conditions within a building during a bushfire event.

Not in NCC 2025. No VIC G5P2 in NCC 2025 Volume One.