Western Australia variation · NCC 2022 Volume One

WA I4D5 Handrails to ramps, flights and landings

WA Part I4 Public buildings

Open on NCC Online ↗

(1) For a WA public building, handrails must be located along—

both sides of a ramp or flight; and

each side of a landing, except for that part of a side that is interrupted by a ramp or flight.

(2) The requirements of (1) do not apply to—

handrails referred to in D3D23; or

handrails located within a fire-isolated stairway or fire-isolated ramp.

Changed in NCC 2025. See NCC 2025 Volume One WA I4D5, or show what changed.

Delete clause I4D5 and insert WA I4D5 as follows: (1) For a WA public building, handrails must be located … or handrails located within a fire-isolated stairway or fire-isolated ramp.

Removed words are struck through; added words are highlighted. Comparison of the text only.