Western Australia variation · NCC 2025 Volume One
WA I4D5 Handrails to ramps, flights and landings
WA Part I4 Public buildings
Delete clause I4D5 and insert WA I4D5 as follows:
(1) For a WA public building, handrails must be located along—
both sides of a ramp or flight; and
each side of a landing, except for that part of a side that is interrupted by a ramp or flight.
(2) The requirements of (1) do not apply to—
handrails referred to in D3D23; or
handrails located within a fire-isolated stairway or fire-isolated ramp.
Changed since NCC 2022. See NCC 2022 Volume One WA I4D5, or show what changed.
Delete clause I4D5 and insert WA I4D5 as follows: (1) For a WA public building, handrails must be located … or handrails located within a fire-isolated stairway or fire-isolated ramp.
Removed words are struck through; added words are highlighted. Comparison of the text only.
Other states and territories
- NSW Delete clause I4D5 and insert NSW I4D5 as follows: NSW I4D6 to NSW I4D9 apply to a conventional stage, that is, a…
- SA Delete clause I4D5 and insert SA I4D5 as follows: (1) In addition to any horizontal exit, not less than 2 exits must…
- TAS Delete clause I4D5 and insert TAS I4D5 as follows: Premises satisfy TAS I4P4 where— a grease trap, an overflow…