Deemed-to-Satisfy Provision · NCC 2022 Volume Three

B6D4 Water efficiency

Part B6 Rainwater services

Open B6D4 on NCC Online ↗

(1) Cisterns or flushing devices for water closet pans must—

be a minimum of 3 Star WELS rating, discharging not more than 6 litres or 4.5 litres for a full flush; and

have a dual flushing mechanism.

(2) Cisterns or flushing devices for urinals must—

be a minimum of 2 Stars WELS rating, discharging not more than 2.5 litres; and

serve a single stall or 600 mm length of continuous urinal wall; and

not be automatic or set-cycle.

Applications

The flush volumes of B6D4 may be within a tolerance of—

±0.5 litres for the full flush of a 6/3 litre cistern; or

+0.5 litres for the reduced flush of a 6/3 litre cistern; or

±0.2 litres for a 4.5/3 litre cistern.

Exemptions

The requirements of B6D4 do not apply to a vacuum drainage system.

The requirements of B6D4(2)(c) do not apply to a programmed solenoid operated flushing system if programmed to shut down during extended periods of non-occupancy of a building.

Same wording in NCC 2025 Volume Three. See NCC 2025 Volume Three B6D4.
Can't meet B6D4? A Performance Solution must meet the Performance Requirements it satisfies: B6P1, B6P2, B6P3, B6P4, B6P5, B6P6. Start a Performance Solution →

Defined terms used