B6D4 Water efficiency
(1) Cisterns or flushing devices for water closet pans must—
be a minimum of 3 Star WELS rating, discharging not more than 6 litres or 4.5 litres for a full flush; and
have a dual flushing mechanism.
(2) Cisterns or flushing devices for urinals must—
be a minimum of 2 Stars WELS rating, discharging not more than 2.5 litres; and
serve a single stall or 600 mm length of continuous urinal wall; and
not be automatic or set-cycle.
Applications
The flush volumes of B6D4 may be within a tolerance of—
±0.5 litres for the full flush of a 6/3 litre cistern; or
+0.5 litres for the reduced flush of a 6/3 litre cistern; or
±0.2 litres for a 4.5/3 litre cistern.
Exemptions
The requirements of B6D4 do not apply to a vacuum drainage system.
The requirements of B6D4(2)(c) do not apply to a programmed solenoid operated flushing system if programmed to shut down during extended periods of non-occupancy of a building.