- B6O1 ObjectiveThe Objective of this Part is to— safeguard people from illness, injury or loss (including loss of amenity) due to the failure of a rainwater…
- B6F1 Rainwater serviceA rainwater service must be designed and installed so as to operate in a way that avoids the likelihood of inadvertent contamination of any drinking…
- B6P1 PressureThe points of discharge of a rainwater service must— have— a working pressure of not less than 50 kPa; and a static pressure within a building of…
- B6P2 VelocityA rainwater service must ensure pipework water velocity does not exceed 3 m/s for more than 1% of the time that the water is required during the…
- B6P3 Water efficiencyA rainwater service must ensure the efficient use of water by— limiting water usage from— a cistern or flushing device for a urinal, to a flush…
- B6P4 Access and isolationA rainwater service must ensure access for maintenance of mechanical components and operational controls. A rainwater service must ensure the…
- B6P5 IdentificationPipes and pipe outlets that form part of a rainwater service must be clearly identified.
- B6P6 Uncontrolled dischargeA rainwater service must avoid the likelihood of failure and uncontrolled discharge.
- B6D1 Deemed-to-Satisfy Provisions VICWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements B6P1 to B6P6 are satisfied by complying with B6D2 to B6D6. (2) Where a…
- B6D2 General requirements SA VICA rainwater service must comply with Section 15 of AS/NZS 3500.1.
- B6D3 IdentificationIdentification of rainwater pipework and outlets must be in accordance with Section 15 of AS/NZS 3500.1.
- B6D4 Water efficiencyCisterns or flushing devices for water closet pans must— be a minimum of 3 Star WELS rating, discharging not more than 6 litres or 4.5 litres for a…
- B6D5 Access and isolationAccess for maintenance of mechanical components and operational controls must be provided in accordance with AS/NZS 3500.1. (2) Isolation of…
- B6D6 Bushfire prone areasA rainwater service in a designated bushfire prone area must be in accordance with AS 3959.