Table · NCC 2022 Volume Three
Table C1V1b Discharge units
Part C1 Sanitary plumbing systems
| Fixture | System 1 | System 2 | System 3 |
|---|---|---|---|
| Basin | 0.5 | 0.3 | 0.3 |
| Shower | 0.6 | 0.4 | 0.4 |
| Urinal | 0.8 | 0.5 | 0.4 |
| Bath | 0.8 | 0.6 | 1.3 |
| Kitchen sink | 0.8 | 0.6 | 1.3 |
| Water closet | 2.0 | 1.8 | 1.2 |
| Washing machine - up to 6 kg | 0.8 | 0.6 | 0.6 |
| Domestic dishwasher | 0.8 | 0.6 | 0.2 |
Table for C1V1 Determination of sanitary plumbing wastewater flowrates
Changed in NCC 2025. See NCC 2025 Volume Three Table C1V1b, or show what changed.
Fixture | System 1 | System 2 | System 3 Discharge Units (DU) Basin | 0.3 Bath (with shower) | 0.5 Bath (without shower) | 0.3 0.6 Bidet | 0.3 Shower | 0.6 | 0.4 (single) | 0.4 Urinal | 0.8 (wall-hung) | 0.5 Urinal (stall for each 600 mm length of slab) | 0.4 Bath | 0.8 | 0.6 | 1.3 0.2 Kitchen sink | 0.8 | 0.6 | 1.3 Water closet | 2.0 (6L cistem) | 1.8 Water closet (4L cistem) | 1.2 1.8 Washing machine - up to 6 kg | 0.8 | 0.6 | 0.6 Domestic dishwasher | 0.8 0.6 Floor waste gully | 0.6 | 0.2 Sum of DU from connected fixtures
Removed words are struck through; added words are highlighted. Comparison of the text only.