TAS B2D2 Water heater in a heated water supply system
Part B2 Heated water services · varies B2D2 Water heater in a heated water supply system
Delete clause B2D2 and insert TAS B2D2 as follows:
In a new Class 1 or Class 10 building—
a water heater in a heated water supply system must be—
a solar water heater complying with (b); or
a heat pump water heater complying with (b); or
a gas water heater complying with (c); or
an electric resistance water heater complying with AS/NZS 3500.4; or
a wood fired thermosiphon water heater or direct fired water heater each complying with AS/NZS 3500.4; and
a solar water heater and a heat pump water heater must have—
for a building with 1 or 2 bedrooms—
at least 14 Small-scale Technology Certificates for the zone where it is being installed; or
an energy saving of not less than 40% in accordance with AS/NZS 4234 for a "small" load system; and
for a building with 3 or 4 bedrooms—
at least 22 Small-scale Technology Certificates for the zone where it is being installed; or
an energy saving of not less than 60% in accordance with AS/NZS 4234 for a "medium" load system; and
for a building with more than 4 bedrooms—
at least 28 Small-scale Technology Certificates for the zone where it is being installed; or
an energy saving of not less than 60% in accordance with AS/NZS 4234 for a “large” load system; and
a gas water heater must be rated not less than 5 stars in accordance with AS 4552.
The national clause
Other states and territories
- VIC Insert VIC subclause B2D2(5) in clause B2D2 as follows: (5) A solar water heater system installed in a new Class 1…
- NSW This clause been deliberately left blank Compliance is not required with the national provisions of B2D2 as the…
- QLD This clause been deliberately left blank
- SA Delete clause B2D2 and insert SA B2D2 as follows: (1) In an established Class 1 building connected to a reticulated…