- SA A6G7 Class 6 buildingsDelete clause A6G7 and insert SA A6G7 as follows: A Class 6 building is a shop or other building for the sale of goods by retail or the supply of…
- SA B2D2 Water heater in a heated water supply systemDelete clause B2D2 and insert SA B2D2 as follows: (1) In an established Class 1 building connected to a reticulated gas supply or a new Class 1 or…
- SA B2D5 Maximum delivery temperatureDelete clause B2D5 and insert SA B2D5 as follows: (1) The delivery temperature of heated water at the outlet of each sanitary fixture must be— not…
- SA B2D9 General requirementsDelete clause B2D9 and insert SA B2D9 as follows: A heated water service must be in accordance with AS/NZS 3500.4 with the following variations—…
- SA B5D6 RainwaterDelete clause B5D6 and insert SA B5D6 as follows: Protection of drinking water services from rainwater must be in accordance with AS/NZS…
- SA B6D2 General requirementsDelete clause B6D2 and insert SA B6D2 as follows: A rainwater service must comply with Section 15 of AS/NZS 3500.1. Additionally, after Clause…
- SA C1D3 General requirementsDelete clause C1D3 and insert SA C1D3 as follows: A sanitary plumbing system must be in accordance with AS/NZS 3500.2 with the following variations:…
- SA C2D4 General requirementsDelete clause C2D4 and insert SA C2D4 as follows: A sanitary drainage system must be in accordance with AS/NZS 3500.2 with the following variations:…
- SA C3D2 Septic tanksDelete clause C3D2 and insert SA C3D2 as follows: A septic tank must be in accordance with the South Australia On-Site Wastewater Systems Code.
- SA C3D3 Composting toiletsDelete clause C3D3 and insert SA C3D3 as follows: A waterless composting toilet must be in accordance with the South Australia On-Site Wastewater…
- SA C3D4 Secondary treatment systemsDelete clause C3D4 and insert SA C3D4 as follows: A secondary treatment system must be in accordance with the South Australia On-Site Wastewater…
- SA C3D5 Domestic grey water treatment systemsDelete clause C3D5 and insert SA C3D5 as follows: A domestic greywater treatment system must be in accordance with the South Australia On-Site…
- SA C3D6 Land application systemsDelete clause C3D6 and insert SA C3D6 as follows: A land application system must be in accordance with the South Australia On-Site Wastewater…
- SA C3D7 Common effluent drainage systemsDelete clause C3D7 and insert SA C3D7 as follows: A common effluent drainage system must be in accordance the South Australia Community Wastewater…