Deemed-to-Satisfy Provision · NCC 2022 Volume Two

H6D2 Application of Part H6

Part H6 Energy efficiency · NCC 2019: 3.12.0, NSW 3.12.1, NSW 3.12.3, NSW 3.12.5

Open H6D2 on NCC Online ↗
Varied in NSW, NT, VIC. Check the variation for your state.

(1) Performance RequirementH6P1 for the thermal performance of the building is satisfied by—

complying with S42C2, using house energy rating software and S42C4(1); or

complying with the following parts of the ABCB Housing Provisions—

Part 13.2, for the building fabric; and

Part 13.3, for the external glazing and shading; and

Part 13.4, for building sealing; and

Part 13.5, for ceiling fans.

(2) Performance RequirementH6P2 for the energy usage of the building is satisfied by—

complying with S42C3 using house energy rating software and S42C4(2); or

complying with Parts 13.6 and 13.7 of the ABCB Housing Provisions for a building with a total floor area not greater than 500 m².

Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two H6D2.

State and territory variations all clauses side by side →

Clauses referred to

Defined terms used