NCC 2022 Volume Two
Part H6 Energy efficiency
13 clauses · Open on NCC Online ↗
- H6O1 Objective NTThe Objective of this Part is to — reduce energy consumption and energy peak demand; and reduce greenhouse gas emissions; and improve occupant…
- H6F1 Energy efficiency NTA building must— reduce the energy consumption and energy peak demand of key energy using equipment; and reduce greenhouse gas emissions that occur…
- H6P1 Thermal performance NSW NTThe total heating load of the habitable rooms and conditioned spaces in a building must not exceed the heating load limit in Specification 44. (2)…
- H6P2 Energy usage NSW NTThe energy value of a building’s domestic services must not exceed 70% of the energy value with— a 3-star ducted heat pump, rated under the 2019…
- H6V1 Application of H6V2 and H6V3 NSW NT VICThe Verification Methods in this Part only apply to— a Class 1 building; and an enclosed Class 10a building attached to a Class 1 building.
- Table H6V2a Heating and cooling schedulesHour ending at | Habitable rooms other than bedrooms | Bedrooms 1:00 | OFF | ON 2:00 | OFF | ON 3:00 | OFF | ON 4:00 | OFF | ON 5:00 | OFF | ON 6:00…
- Table H6V2b Occupancy and cooking equipment loadsFloor area of habitable rooms (m²) | Occupancy (m²/occupant) | Cooking equipment load (W/m² of kitchen area) 100 | 41.2 | 36.2 125 | 44.3 | 34.7 150…
- Table H6V2c Occupancy schedulesHour ending at | Weekday occupancy in habitable rooms other than bedrooms | Weekend occupancy in habitable rooms other than bedrooms | Weekday and…
- Table H6V2d Lighting, cooking and appliance schedulesHour ending at | Lighting | Cooking | Appliances 1:00 | 0% | 0% | 45% 2:00 | 0% | 0% | 40% 3:00 | 0% | 0% | 40% 4:00 | 0% | 0% | 40% 5:00 | 0% | 0%…
- H6V2 Verification using a reference building NSW NTCompliance with H6P1 is verified when a proposed building— compared to a reference building, using a calculation method other than house energy…
- H6V3 Verification of building envelope sealing NSWCompliance with H6P1 is verified for building envelope sealing when a building envelope is sealed at an air permeability of not more than 10…
- H6D1 Deemed-to-Satisfy Provisions NSW NTWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements H6P1 and H6P2 are satisfied by complying with H6D2. (2) Where a Performance…
- H6D2 Application of Part H6 NSW NT VICPerformance RequirementH6P1 for the thermal performance of the building is satisfied by— complying with S42C2, using house energy rating software…