Housing Provisions clause · ABCB Housing Provisions 2025

3.4.1 Requirements for termite management systems

Part 3.4 Termite risk management · NCC 2019: 3.1.4.2

Open 3.4.1 on NCC Online ↗
Varied in NT, QLD. Check the variation for your state.

(1) The requirements of this Part apply where:

a Class 1 or 10 building is constructed in an area where subterranean termites are known to present a potential risk of attack; and

a primary building element of a Class 1 or 10 building is considered susceptible to termite attack.

(2) For the purposes of (1), a primary building element consisting entirely of, or a combination of, any of the following materials is considered not subject to termite attack:

Steel, aluminium or other metals.

Concrete.

Masonry.

Fibre-reinforced cement.

Timber — naturally termite resistant in accordance with Appendix C of AS 3660.1.

Timber — preservative treated in accordance with Appendix D of AS 3660.1.

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 3.4.1.

State and territory variations all clauses side by side →

Defined terms used