- 10.7.1 Sound insulation requirements NTA separating wall between Class 1 buildings, or a wall that separates a Class 1 building from a Class 10a building which is not associated with the…
- 10.7.2 Determination of airborne sound insulation ratings NTThe Rw + Ctr sound insulation rating required by 10.7.1(1)(a) must— be determined in accordance with AS ISO 717.1, using results from laboratory…
- 10.7.3 Construction of sound insulated walls NTTo achieve the appropriate level of sound insulation, walls must be constructed as follows: Stud wall junction — junctions of sound insulated walls…
- 10.7.4 ServicesServices must not be chased into concrete or masonry separating walls. (2) If a duct, soil, waste, water supply or stormwater pipe is located in a…
- 10.7.5 Acceptable forms of construction for masonry wallsAcceptable forms of construction for masonry walls are set out in (2) to (6). (2) Two leaves of 110 mm clay brick masonry with— a cavity not less…
- 10.7.6 Acceptable forms of construction for concrete wallsAcceptable forms of construction for concrete walls are set out in (2) to (5). (2) 150 mm thick plain off form concrete, has an Rw + Ctr of not less…
- 10.7.7 Acceptable forms of construction for autoclaved aerated concrete wallsAcceptable forms of construction for autoclaved aerated concrete walls are set out in (2) to (4). (2) A 75 mm thick autoclaved aerated concrete wall…
- 10.7.8 Acceptable forms of construction for timber and steel framed wallsAcceptable forms of construction for timber and steel framed walls are set out in (2) and (3). (2) Two rows of 90 mm x 35 mm timber studs or two…