Table 13.3.3a Constant for solar heat gain coefficient (CSHGC): climate zones 1 to 7
| Floor type | Ventilation opening area | Climate zone | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 (lightweight wall) | 5 (concrete or brick wall) | 6 | 7 | ||
| Floor in direct contact with the ground | 5% | 0.0672 | 0.0595 | 0.0945 | 0.0604 | 0.0484 | 0.0657 | 0.0786 | 0.0762 |
| 10% | 0.0718 | 0.0640 | 0.0985 | 0.0626 | 0.0538 | 0.0695 | 0.0817 | 0.0821 | |
| 15% | 0.0770 | 0.0682 | 0.1001 | 0.0641 | 0.0569 | 0.0714 | 0.0832 | 0.0871 | |
| 20% | 0.0827 | 0.0719 | 0.1007 | 0.0650 | 0.0587 | 0.0723 | 0.0840 | 0.0912 | |
| Suspended floor | 5% | 0.0431 | 0.0324 | 0.0768 | 0.0651 | 0.0334 | 0.0630 | 0.0963 | 0.0750 |
| 10% | 0.0497 | 0.0404 | 0.0783 | 0.0697 | 0.0426 | 0.0683 | 0.0989 | 0.0778 | |
| 15% | 0.0541 | 0.0458 | 0.0792 | 0.0721 | 0.0477 | 0.0710 | 0.1001 | 0.0789 | |
| 20% | 0.0570 | 0.0494 | 0.0796 | 0.0734 | 0.0505 | 0.0723 | 0.1007 | 0.0793 |
Table Notes
The ventilation opening area is the total area of each ventilation opening divided by the floor area of the storey, including any mezzanine.
No window may have a design ventilation opening greater than 90% because the window frame will always obstruct some of the area of the opening.
Where the ventilation opening area is more than 20%, the CSHGC value corresponding to 20% ventilation opening area is to be used.
Where the floor construction of a storey, including any mezzanine, is partly in direct contact with the ground and partly suspended, the constant is to be—
interpolated between the constants in proportion to the floor area of each floor type; or
the constant for a suspended floor.
If the ventilation opening area is between the values shown in this Table, the constant may be interpolated.
Table for 13.3.3 External glazing — summer