Table · ABCB Housing Provisions 2022
Table 13.3.3u Summer solar heat gain factors: climate zone 4
| Type factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor |
|---|---|---|
| Room factor (RS) for a bedroom and a room which is not a conditioned space | 0.35 | 0.80 |
| Level factor (LS) for all other floor levels | 1.10 | 1.20 |
| Frame factor (FS) for frames with a solar absorptance of ≤ 0.40 | 0.88 | 0.88 |
| Frame factor (FS) for frames with a solar absorptance of > 0.40 to < 0.68 | 1.00 | 0.91 |
| Frame factor (FS) for frames with a solar absorptance of ≥ 0.68 | 1.19 | 1.00 |
| Floor factor (for tiled or vinyl covered floor) (HS) | 0.91 | Not applicable |
Table Notes
Where a factor is listed as ‘Not applicable’, the value of the factor must be taken as 1.0.
Table for 13.3.3 External glazing — summer
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3u.