Table · ABCB Housing Provisions 2025

Table 6.3.3c Maximum bearer span (m) — single span — bearer supporting tiled floor and 3 m high non-loadbearing internal wall

Part 6.3 Structural steel members

Open Table 6.3.3c on NCC Online ↗
Steel sectionEffective load width (m)
1.82.43.03.64.2
125 TFB3.93.73.53.43.3
180 UB 16.15.25.04.84.64.4
200 UB 18.25.95.65.45.25.0
250 UB 25.77.77.37.16.86.6
250 x 150 x 9 RHS8.78.38.07.77.5
250 x 150 x 5 RHS7.57.16.96.66.1
310 UB 32.09.38.98.58.28.0
125 x 75 x 2 RHS2.72.42.22.01.9
125 x 75 x 3 RHS3.23.02.92.72.5
150 x 50 x 2 RHS3.02.72.42.22.1
150 x 50 x 3 RHS3.43.33.12.92.7
100 TFB2.72.62.52.32.2
150 PFC4.84.64.44.24.1
180 PFC5.75.45.25.04.9
200 PFC6.36.05.85.65.4
250 PFC8.37.97.67.37.1
300 PFC9.79.28.98.68.3

Table Notes

Load accounted for includes 0.98 kPa permanent floor, 0.92 kN/m permanent wall, permanent member self-weight, 1.5 kPa or 1.1 kN imposed.

Load combinations included are 1.35G and 1.25G+1.5Q for ULS and G + 0.7Q for SLS with a maximum deflection of span/300.

Bearers are assumed to have intermediate lateral restraints at joist locations and are considered fully laterally restrained.

Table for 6.3.3 Bearers

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 6.3.3c.