6.3.3 Bearers
Part 6.3 Structural steel members
Structural steel bearers must comply with the following:
Effective bearer spacing must be determined in accordance with—
for single span joists — Table H1D6a and Figure H1D6d; and
for continuous span joists — Table H1D6b and Figure H1D6e.
Maximum acceptable bearer spans must be determined in accordance with—
for single spans — Tables 6.3.3a and 6.3.3c; and
for continuous spans — Tables 6.3.3b and 6.3.3d.
All loads along the bearer must be evenly distributed.
The difference in distance between supports for continuous span bearers must not be more than 10% of the span.
Fixing of joists and columns to structural steel bearers must comply with 6.3.7.
Bearers must be supported by structural steel columns that comply with 6.3.6 and are fixed in accordance with 6.3.7.
Table 6.3.3a Maximum bearer span (m) — single span — bearer supporting timber floor and 3 m high non-loadbearing internal wall
Steel section
Effective load width (m)
1.8
2.4
3.0
3.6
4.2
125 TFB
4.2
4.0
3.9
3.8
3.6
180 UB 16.1
5.6
5.4
5.3
5.1
4.7
200 UB 18.2
6.4
6.2
6.0
5.8
5.4
250 UB 25.7
8.3
8.0
7.8
7.6
7.1
250 x 150 x 9 RHS
9.3
9.0
8.8
8.6
8.4
250 x 150 x 5 RHS
8.0
7.8
7.6
7.1
6.6
310 UB 32.0
10.0
9.7
9.4
9.2
8.6
125 x 75 x 2 RHS
2.9
2.6
2.3
2.2
2.0
125 x 75 x 3 RHS
3.5
3.3
3.2
2.9
2.7
150 x 50 x 2 RHS
3.3
2.9
2.6
2.4
2.3
150 x 50 x 3 RHS
3.7
3.6
3.4
3.1
2.9
100 TFB
2.9
2,8
2.7
2.5
2.4
150 PFC
5.2
5.0
4.9
4.7
4.6
180 PFC
6.1
5.9
5.8
5.6
5.4
200 PFC
6.8
6.6
6.4
6.2
5.9
250 PFC
8.9
8.6
8.4
8.2
8.0
300 PFC
10.4
10.1
9.8
9.5
9.3
Table Notes
Load accounted for includes 0.53 kPa permanent floor, 0.92 kN/m permanent wall, permanent member self-weight, 1.5 kPa or 1.1 kN imposed.
Load combinations included are 1.35G and 1.25G+1.5Q for ULS and G + 0.7Q for SLS with a maximum deflection of span/300.
Bearers are assumed to have intermediate lateral restraints at joist locations and are considered fully laterally restrained.
Table 6.3.3b Maximum bearer span (m) — continuous span — bearer supporting timber floor and 3 m high non-loadbearing internal wall
Steel section
Effective load width (m)
1.8
2.4
3.0
3.6
4.2
125 TFB
5.2
4.6
4.2
3.9
3.6
180 UB 16.1
6.8
6.0
5.5
5.1
4.7
200 UB 18.2
7.7
6.9
6.2
5.8
5.4
250 UB 25.7
10.2
9.1
8.3
7.6
7.1
250 x 150 x 9 RHS
12.4
11.5
10.5
9.8
9.1
250 x 150 x 5 RHS
9.5
8.4
7.7
7.1
6.6
310 UB 32.0
12.3
11.0
10.0
9.2
8.6
125 x 75 x 2 RHS
2.9
2.6
2.3
2.2
2.0
125 x 75 x 3 RHS
4.0
3.5
3.2
2.9
2.7
150 x 50 x 2 RHS
3.3
2.9
2.6
2.4
2.3
150 x 50 x 3 RHS
4.2
3.7
3.4
3.1
2.9
100 TFB
3.4
3.0
2.7
2.5
2.4
150 PFC
6.5
5.8
5.3
4.9
4.6
180 PFC
7.8
6.9
6.3
5.8
5.4
200 PFC
8.5
7.6
6.9
6.4
5.9
250 PFC
11.6
10.4
9.5
8.7
8.2
300 PFC
13.4
12.0
10.9
10.1
9.4
Table Notes
Load accounted for includes 0.53 kPa permanent floor, 0.92 kN/m permanent wall, permanent member self-weight, 1.5 kPa or 1.1 kN imposed.
Load combinations included are 1.35G and 1.25G+1.5Q for ULS and G + 0.7Q for SLS with a maximum deflection of span/300.
Bearers are assumed to have intermediate lateral restraints at joist locations and are considered fully laterally restrained.
Table 6.3.3c Maximum bearer span (m) — single span — bearer supporting tiled floor and 3 m high non-loadbearing internal wall
Steel section
Effective load width (m)
1.8
2.4
3.0
3.6
4.2
125 TFB
3.9
3.7
3.5
3.4
3.3
180 UB 16.1
5.2
5.0
4.8
4.6
4.4
200 UB 18.2
5.9
5.6
5.4
5.2
5.0
250 UB 25.7
7.7
7.3
7.1
6.8
6.6
250 x 150 x 9 RHS
8.7
8.3
8.0
7.7
7.5
250 x 150 x 5 RHS
7.5
7.1
6.9
6.6
6.1
310 UB 32.0
9.3
8.9
8.5
8.2
8.0
125 x 75 x 2 RHS
2.7
2.4
2.2
2.0
1.9
125 x 75 x 3 RHS
3.2
3.0
2.9
2.7
2.5
150 x 50 x 2 RHS
3.0
2.7
2.4
2.2
2.1
150 x 50 x 3 RHS
3.4
3.3
3.1
2.9
2.7
100 TFB
2.7
2.6
2.5
2.3
2.2
150 PFC
4.8
4.6
4.4
4.2
4.1
180 PFC
5.7
5.4
5.2
5.0
4.9
200 PFC
6.3
6.0
5.8
5.6
5.4
250 PFC
8.3
7.9
7.6
7.3
7.1
300 PFC
9.7
9.2
8.9
8.6
8.3
Table Notes
Load accounted for includes 0.98 kPa permanent floor, 0.92 kN/m permanent wall, permanent member self-weight, 1.5 kPa or 1.1 kN imposed.
Load combinations included are 1.35G and 1.25G+1.5Q for ULS and G + 0.7Q for SLS with a maximum deflection of span/300.
Bearers are assumed to have intermediate lateral restraints at joist locations and are considered fully laterally restrained.
Table 6.3.3d Maximum bearer span (m) — continuous span — bearer supporting tiled floor and 3 m high non-loadbearing internal wall
Steel section
Effective load width (m)
1.8
2.4
3.0
3.6
4.2
125 TFB
4.8
4.3
3.9
3.6
3.3
180 UB 16.1
6.3
5.6
5.1
4.7
4.4
200 UB 18.2
7.2
6.4
5.8
5.3
5.0
250 UB 25.7
9.5
8.5
7.7
7.1
6.6
250 x 150 x 9 RHS
11.6
10.8
9.8
9.1
8.5
250 x 150 x 5 RHS
8.8
7.8
7.1
6.6
6.1
310 UB 32.0
11.5
10.2
9.3
8.5
8.0
125 x 75 x 2 RHS
2.7
2.4
2.2
2.0
1.9
125 x 75 x 3 RHS
3.7
3.3
3.0
2.7
2.5
150 x 50 x 2 RHS
3.1
2.7
2.4
2.2
2.1
150 x 50 x 3 RHS
3.9
3.4
3.1
2.9
2.7
100 TFB
3.2
2.8
2.5
2.3
2.2
150 PFC
6.1
5.4
4.9
4.5
4.2
180 PFC
7.2
6.4
5.8
5.4
5.0
200 PFC
8.0
7.1
6.4
5.9
5.5
250 PFC
10.9
9.7
8.8
8.1
7.6
300 PFC
12.5
11.2
10.1
9.4
8.7
Table Notes
Load accounted for includes 0.98 kPa permanent floor, 0.92 kN/m permanent wall, permanent member self-weight, 1.5 kPa or 1.1 kN imposed.
Load combinations included are 1.35G and 1.25G+1.5Q for ULS and G + 0.7Q for SLS with a maximum deflection of span/300.
Bearers are assumed to have intermediate lateral restraints at joist locations and are considered fully laterally restrained.
Tables
- Table 6.3.3a Maximum bearer span (m) — single span — bearer supporting timber floor and 3 m high non-loadbearing internal wall
- Table 6.3.3b Maximum bearer span (m) — continuous span — bearer supporting timber floor and 3 m high non-loadbearing internal wall
- Table 6.3.3c Maximum bearer span (m) — single span — bearer supporting tiled floor and 3 m high non-loadbearing internal wall
- Table 6.3.3d Maximum bearer span (m) — continuous span — bearer supporting tiled floor and 3 m high non-loadbearing internal wall