Table · NCC 2025 Volume Three

Table C2V3a Frequency factors

Part C2 Sanitary drainage systems

Open Table C2V3a on NCC Online ↗
NCC building classNCC building class exampleFrequency factor (K)Time interval between fixture use averaged over peak period (s)
Class 1Residential dwelling, duplexes, or townhouses0.51200
Class 2Apartment or unit0.5 - 0.8450 - 1200
Class 3Hotel, hostel, dormitory0.6 - 0.8450 - 800
Class 4Sole dwelling within a Class 5-9 building0.51200
Class 5Office0.6 - 0.8450 - 800
Class 6Retail, shop, restaurant, café0.6 - 0.8450 - 800
Class 7Carpark, warehouse, storage building0.6 - 0.8450 - 800
Class 8Factory, workshop, laboratory0.6 - 0.8450 - 800
Class 9aHealthcare building, hospital, and GP clinics0.6 - 0.8450 - 800
Class 9bPublic event buildings, stadiums, theatres, schools, universities, and churches1.0 - 1.2200 - 300
Class 9cAged care facilities0.6 - 0.8450 - 800

Table for C2V3 Determination of sanitary drainage wastewater flowrates

Changed since NCC 2022. See NCC 2022 Volume Three Table C2V3a, or show what changed.

Fixture usage NCC building class | NCC building class example | Frequency factor (K) Intermittent | Time interval between fixture use e.g. averaged over peak period (s) Class 1 | Residential dwelling, guesthouse duplexes, or office townhouses | 0.5 | 1200 Class 1, Class 2, 2 | Apartment or unit | 0.5 - 0.8 | 450 - 1200 Class 3 or | Hotel, hostel, dormitory | 0.6 - 0.8 | 450 - 800 Class 4 | Sole dwelling within a Class 5-9 building | 0.5 Frequent use e.g. hospital, restaurant or hotel | 1200 Class 5, 5 | Office | 0.6 - 0.8 | 450 - 800 Class 6, 6 | Retail, shop, restaurant, café | 0.6 - 0.8 | 450 - 800 Class 7, 7 | Carpark, warehouse, storage building | 0.6 - 0.8 | 450 - 800 Class 8, 8 | Factory, workshop, laboratory | 0.6 - 0.8 | 450 - 800 Class 9a or | Healthcare building, hospital, and GP clinics | 0.6 - 0.8 | 450 - 800 Class 9b | Public event buildings, stadiums, theatres, schools, universities, and churches | 1.0 - 1.2 | 200 - 300 Class 9c | 0.7 Congested use e.g. open to the general public, school Aged care facilities | Class 9b 0.6 - 0.8 | 1.0 Special use e.g. laboratory | Not applicable | 1.2 450 - 800

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used