Table C2V3b Discharge units
Part C2 Sanitary drainage systems
| Fixture | Discharge Units (DU) |
|---|---|
| Basin | 0.3 |
| Bath (with shower) | 0.5 |
| Bath (without shower) | 0.6 |
| Bidet | 0.3 |
| Shower (single) | 0.4 |
| Urinal (wall-hung) | 0.5 |
| Urinal (stall for each 600 mm length of slab) | 0.2 |
| Kitchen sink | 0.6 |
| Water closet (6L cistern) | 1.8 |
| Water closet (4L cistern) | 1.8 |
| Washing machine | 0.6 |
| Domestic dishwasher | 0.6 |
| Floor waster gully | Sum of DU from connected fixtures |
Table for C2V3 Determination of sanitary drainage wastewater flowrates
Changed since NCC 2022. See NCC 2022 Volume Three Table C2V3b, or show what changed.
Fixture | System 1 - Discharge Units (DU) | System 2 - Discharge Units (DU) | System 3 - Discharge Units (DU) Basin | 0.3 Bath (with shower) | 0.5 Bath (without shower) | 0.3 0.6 Bidet | 0.3 Shower | 0.6 | 0.4 (single) | 0.4 Urinal | 0.8 (wall-hung) | 0.5 Urinal (stall for each 600 mm length of slab) | 0.4 Bath | 0.8 | 0.6 | 1.3 0.2 Kitchen sink | 0.8 | 0.6 | 1.3 Water closet | 2.0 (6L cistern) | 1.8 Water closet (4L cistern) | 1.2 1.8 Washing machine - Up to 6 kg | 0.8 | 0.6 | 0.6 Domestic dishwasher | 0.8 0.6 Floor waster gully | 0.6 | 0.2 Sum of DU from connected fixtures
Removed words are struck through; added words are highlighted. Comparison of the text only.