Table C2V3b Discharge units

Part C2 Sanitary drainage systems

Open Table C2V3b on NCC Online ↗
FixtureDischarge Units (DU)
Basin0.3
Bath (with shower)0.5
Bath (without shower)0.6
Bidet0.3
Shower (single)0.4
Urinal (wall-hung)0.5
Urinal (stall for each 600 mm length of slab)0.2
Kitchen sink0.6
Water closet (6L cistern)1.8
Water closet (4L cistern)1.8
Washing machine0.6
Domestic dishwasher0.6
Floor waster gullySum of DU from connected fixtures

Table for C2V3 Determination of sanitary drainage wastewater flowrates

Changed since NCC 2022. See NCC 2022 Volume Three Table C2V3b, or show what changed.

Fixture | System 1 - Discharge Units (DU) | System 2 - Discharge Units (DU) | System 3 - Discharge Units (DU) Basin | 0.3 Bath (with shower) | 0.5 Bath (without shower) | 0.3 0.6 Bidet | 0.3 Shower | 0.6 | 0.4 (single) | 0.4 Urinal | 0.8 (wall-hung) | 0.5 Urinal (stall for each 600 mm length of slab) | 0.4 Bath | 0.8 | 0.6 | 1.3 0.2 Kitchen sink | 0.8 | 0.6 | 1.3 Water closet | 2.0 (6L cistern) | 1.8 Water closet (4L cistern) | 1.2 1.8 Washing machine - Up to 6 kg | 0.8 | 0.6 | 0.6 Domestic dishwasher | 0.8 0.6 Floor waster gully | 0.6 | 0.2 Sum of DU from connected fixtures

Removed words are struck through; added words are highlighted. Comparison of the text only.