Verification Method · NCC 2025 Volume Two
H4V2 Verification of suitable natural light
Part H4 Health and amenity · NCC 2019: V2.4.4
Compliance with H4P4(1) is verified for the provision of natural light in all habitable rooms when the average daylight factor for each window is determined in accordance with the following formula: [formula] , where—
[formula] = the net area of the light transmitting area of the window (m2); and
[formula] = the total area of the internal wall, floor and ceiling surfaces (m2); and
[formula] = the diffuse light transmittance of the window; and
[formula] = visible sky angle in degrees, measured in a plane normal to and from the centre of the window; and
[formula] = the area-weighted average reflectance of area [formula] .
Same wording in NCC 2022 Volume Two. See NCC 2022 Volume Two H4V2.