NCC 2025 Volume Two
Part H4 Health and amenity
36 clauses · Open on NCC Online ↗
- H4O1 Wet areasThe Objective is to safeguard the occupants from illness or injury and protect the building from damage caused by the accumulation of internal…
- H4O2 Room heightsThe Objective is to safeguard the occupants from injury or loss of amenity caused by inadequate height of a room or space.
- H4O3 FacilitiesThe Objective is to— safeguard occupants from illness caused by infection; and safeguard occupants from loss of amenity arising from the absence of…
- H4O4 LightThe Objective is to safeguard occupants from injury, illness or loss of amenity due to— isolation from natural light; and lack of adequate…
- H4O5 VentilationThe Objective is to safeguard occupants from illness or loss of amenity due to lack of air freshness.
- H4O6 Sound insulationThe Objective is to safeguard occupants from illness or loss of amenity as a result of undue sound being transmitted between adjoining dwellings.
- H4O7 Condensation and water vapour managementThe Objective is to reduce the likelihood of condensation or water vapour build-up causing illness, injury or loss of amenity for building…
- H4F1 Wet areasA building is to be constructed to avoid the likelihood of— the creation of any unhealthy or dangerous conditions; or damage to building elements,…
- H4F2 Room heightsA building is to be constructed to provide height in a room or space suitable for the intended use.
- H4F3 FacilitiesA building is to be provided with suitable— space and facilities for personal hygiene; and space or facilities for laundering; and space and…
- H4F4 LightA habitable room within a building is to be provided with openings to admit adequate natural light consistent with its function or use. (2) A space…
- H4F5 VentilationA space used by occupants within a building is to be provided with adequate ventilation consistent with its function or use.
- H4F6 Sound insulationA building element which separates dwellings is to be constructed to prevent undue sound transmission between those dwellings.
- H4F7 Condensation and water vapour managementBuilding elements in areas subject to water vapour or condensation must be constructed to reduce risks to the health of building occupants.…
- H4P1 Wet areas SATo protect the structure of the building and to maintain the amenity of the occupants, water must be prevented from penetrating— behind fittings and…
- H4P2 Room heightsA room or space must be of a height that does not unduly interfere with its intended function.
- H4P3 Personal hygiene and other facilitiesSuitable sanitary facilities for personal hygiene must be provided in a convenient location within or associated with a building, appropriate to its…
- H4P4 LightingA habitable room must be provided with windows, where appropriate to the function or use of that part of the building, so that natural light, when…
- H4P5 VentilationA space within a building used by occupants must be provided with means of ventilation with outdoor air which will maintain adequate air quality.…
- H4P6 Sound insulation NTWalls separating dwellings must, to provide insulation against the transmission of airborne sound, have a weighted standardised level difference…
- H4P7 Condensation and water vapour managementRisks associated with water vapour and condensation must be managed to minimise their impact on the health of occupants. Applications H4P7 only…
- H4V1 Room or space heightCompliance with H4P2 is verified where the height of a room or space provides an appropriate activity support level that does not unduly interfere…
- H4V2 Verification of suitable natural lightCompliance with H4P4(1) is verified for the provision of natural light in all habitable rooms when the average daylight factor for each window is…
- Table H4V3 Maximum contaminant limits for acceptable indoor air qualityPollutant | Averaging Time | Maximum Air Quality Value Carbon dioxide, CO2 | 8 hours | 850 ppm Note 1 Carbon monoxide, CO | 15 minutes | 90 ppm…
- H4V3 Verification of indoor air qualityFor a Class 1 building, compliance with H4P5(1) and H4P5(2)(a) is verified when it is determined that the building under typical conditions in use…
- H4V4 Sound insulation NTCompliance with H4P6(1) and (3) to insulate against transmission of airborne sound through walls separating dwellings is verified when it is…
- H4V5 Verification of condensation managementCompliance with Performance Requirement H4P7 is verified for a roof or external wall assembly when it is determined that a mould index of greater…
- H4D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements H4P1 to H4P7 are satisfied by complying with H4D2 to H4D9. (2) Where a…
- H4D2 Wet areasCompliance with AS 3740 or Part 10.2 of the ABCB Housing Provisions satisfies Performance Requirement H4P1 for wet areas provided the wet areas are…
- H4D3 Materials and installation of wet area components and systemsPerformance Requirement H4P1 is satisfied for materials and the installation of wet area components and systems if— building elements in wet areas…
- H4D4 Room heightsCompliance with Part 10.3 of the ABCB Housing Provisions satisfies Performance Requirement H4P2 for room heights.
- H4D5 FacilitiesCompliance with Part 10.4 of the ABCB Housing Provisions satisfies Performance Requirement H4P3 for facilities.
- H4D6 LightCompliance with Part 10.5 of the ABCB Housing Provisions satisfies Performance Requirement H4P4 for lighting.
- H4D7 VentilationExcept for an exhaust fan from a sanitary compartment, laundry, kitchen or bathroom, Performance Requirement H4P5 is satisfied for a mechanical…
- H4D8 Sound insulationCompliance with Part 10.7 of the ABCB Housing Provisions satisfies Performance Requirement H4P6 for sound insulation.
- H4D9 Condensation management NSW TASCompliance with Part 10.8 of the ABCB Housing Provisions satisfies Performance Requirement H4P7 for condensation management. Notes From 1 May 2023…