D3D22 Handrails
Part D3 Construction of exits · NCC 2019: D2.17
(1) Subject to (2), handrails must—
be located along at least one side of the ramp or flight; and
be located along each side if the total width of the stairway or ramp is 2 m or more; and
in a Class 9b building used as a primary school or a building that contains an early childhood centre —
have one handrail fixed at a height of not less than 865 mm; and
in addition to (i), have a handrail—
fixed at a height between 665 mm and 750 mm in a primary school; and
with a cross-sectional dimension not less than 16 mm and not greater than 45 mm as measured in any direction across its centre, fixed at a height between 450 mm and 700 mm in a Class 9b early childhood centre; and
in any other case, be fixed at a height of not less than 865 mm; and
be continuous between stair flight landings and have no obstruction on or above them that will tend to break a hand-hold; and
in a required exit serving an area required to be accessible, be designed and constructed to comply with clause 9 of AS 1428.1, except that clause 9(d) does not apply to a handrail required by (1)(c)(ii).
(2) For the purposes of (1) the following applies.
(1) does not apply to—
handrails referred to in D3D23; and
step ramps, threshold ramps and kerb ramps.
The height required by (1)(c) and (d) is measured above the nosings of stair treads and the floor surface of the ramp, landing or the like.
(3) Handrails—
in a Class 9a health-care building must be provided along at least one side of every passageway or corridor used by patients, and must be—
fixed not less than 50 mm clear of the wall; and
where practicable, continuous for their full length; and
in a Class 9c aged care building must be provided along both sides of every passageway or corridor used by residents, and must be—
fixed not less than 50 mm clear of the wall; and
where practicable, continuous for their full length.
(4) Handrails required to assist people with a disability must be provided in accordance with D4D4.
(5) Handrails to a stairway or ramp within a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building must—
be located along at least one side of the flight or ramp; and
be located along the full length of the flight or ramp, except in the case where a handrail is associated with a barrier, the handrail may terminate where the barrier terminates; and
have the top surface of the handrail not less than 865 mm vertically above the nosings of the stair treads or the floor surface of the ramp; and
have no obstruction on or above them that will tend to break a handhold, except for newel posts, ball type stanchions, or the like.
(6) The requirements of (5) do not apply to—
handrails referred to in D3D23; or
a stairway or ramp providing a change in elevation of less than 1 m; or
a landing; or
a winder where a newel post is installed to provide a handhold.
Changed since NCC 2022. See NCC 2022 Volume One D3D22, or show what changed.
(1) Except for handrails referred to in D3D23, and subject Subject to (2), handrails must — be located along at least … be accessible, be designed and constructed to comply with clause 12 9 of AS 1428.1, except that clause 12(d) 9(d) does not apply to a handrail required by (1)(c)(ii). (2) For the purposes of (1) the following applies. (1) does not apply to — handrails referred to in D3D23; and step ramps, threshold ramps and kerb ramps. The height required by (1)(c) and (d) is measured above … where a newel post is installed to provide a handhold.
Removed words are struck through; added words are highlighted. Comparison of the text only.