D4D4 Parts of buildings to be accessible
Part D4 Access for people with a disability · NCC 2019: D3.3
In a building required to be accessible —
every ramp and stairway, except for ramps and stairways in areas exempted by D4D5, must comply with—
for a ramp, except a fire-isolated ramp, clause 7 of AS 1428.1; and
for a stairway, except a fire-isolated stairway, clause 8 of AS 1428.1; and
for a fire-isolated stairway, clause 8.1(f) and (g) of AS 1428.1; and
every passenger lift must comply with E3D7 and E3D8; and
accessways must have—
passing spaces complying with AS 1428.1 at maximum 20 m intervals on those parts of an accessway where a direct line of sight is not available; and
turning spaces complying with AS 1428.1—
within 2 m of the end of accessways where it is not possible to continue travelling along the accessway; and
at maximum 20 m intervals along the accessway; and
an intersection of accessways satisfies the spatial requirements for a passing and turning space; and
a passing space may serve as a turning space; and
a ramp complying with AS 1428.1 or a passenger lift need not be provided to serve a storey or level other than the entrance storey in a Class 5, 6, 7b or 8 building—
containing not more than 3 storeys; and
with a floor area for each storey, excluding the entrance storey, of not more than 200 m2.
Changed since NCC 2022. See NCC 2022 Volume One D4D4, or show what changed.
In a building required to be accessible — every ramp … with — for a ramp, except a fire-isolated ramp, clause 10 7 of AS 1428.1; and for a stairway, except a fire-isolated stairway, clause 11 8 of AS 1428.1; and for a fire-isolated stairway, clause 11.1(f) 8.1(f) and (g) of AS 1428.1; and every passenger lift must … storey, excluding the entrance storey, of not more than 200 m2; and clause 7.4.1(a) of AS 1428.1 does not apply and is replaced with ‘the pile height or pile thickness shall not exceed 11 mm and the carpet backing thickness shall not exceed 4 mm’; and the carpet pile height or pile thickness dimension, carpet backing thickness dimension and their combined dimension shown in Figure 8 of AS 1428.1 do not apply and are replaced with 11 mm, 4 mm and 15 mm respectively. m2.
Removed words are struck through; added words are highlighted. Comparison of the text only.
Clauses referred to
- D4D5 Exemptions
- E3D7 Passenger lift types and their limitations
- E3D8 Accessible features required for passenger lifts