NCC 2025 Volume One
Part D3 Construction of exits
36 clauses · Open on NCC Online ↗
- D3D1 Deemed-to-Satisfy Provisions NSW SAWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 to D1P10 are satisfied by complying with— D2D2 to D2D23,…
- D3D2 Application of Part NSWExcept for— D3D14, D3D15(a), D3D17, D3D18, D3D19, D3D20, D3D21, D3D22(5), D3D22(6), D3D26 and D3D29, the Deemed-to-Satisfy Provisions of this Part…
- D3D3 Fire-isolated stairways and rampsA stairway or ramp (including any landings) that is required to be within a fire-resisting shaft must be constructed— of non-combustible materials;…
- D3D4 Non-fire-isolated stairways and rampsIn a building having a rise in storeys of more than 2, required stairs and ramps (including landings and any supporting building elements) which are…
- D3D5 Separation of rising and descending stair flightsIf a stairway serving as an exit is required to be fire-isolated— there must be no direct connection between— a flight rising from a storey below…
- D3D6 Open access ramps and balconiesWhere an open access ramp or balcony is provided to meet the smoke hazard management requirements of E2D4 to E2D13, it must— have ventilation…
- D3D7 Smoke lobbiesA smoke lobby required by D2D12 must— have a floor area not less than 6 m2; and be separated from the occupied areas in the storey by walls which…
- D3D8 Installations in exits and paths of travelAccess to service shafts and services other than to fire-fighting or detection equipment as permitted in the Deemed-to-Satisfy Provisions of Section…
- D3D9 Enclosure of space under stairs and rampsFire-isolated stairways and ramps — If the space below a required fire-isolated stairway or fire-isolated ramp is within the fire-isolated shaft, it…
- D3D10 Width of required stairways and rampsA required stairway or ramp that exceeds 2 m in width is counted as having a width of only 2 m unless it is divided by a handrail or barrier…
- D3D11 Pedestrian rampsA fire-isolated ramp may be substituted for a fire-isolated stairway if the construction enclosing the ramp and the width and ceiling height comply…
- D3D12 Fire-isolated passagewaysThe enclosing construction of a fire-isolated passageway must have an FRL when tested for a fire outside the passageway in another part of the…
- D3D13 Roof as open spaceIf an exit discharges to a roof of a building, the roof must— have an FRL of not less than 120/120/120; and not have any roof lights or other…
- Table D3D14 Riser and going dimensionsStairway location | Riser (R) | Going (G)Note 3 | Quantity (2R + G) Max | Min | Max | Min | Max | Min Public | 190 | 115 | 355 | 250 | 700 | 550…
- D3D14 Goings and risers NSWA stairway must have— not more than 18 and not less than 2 risers in each flight; and going (G), riser (R) and quantity (2R + G) in accordance with…
- Table D3D15 Slip-resistance classificationApplication | Dry surface conditions | Wet surface conditions Ramp steeper than 1:14 | P4 or R11 | P5 or R12 Ramp steeper than 1:20 but not steeper…
- D3D15 LandingsIn a stairway— landings having a maximum gradient of 1:50 may be used in any building to limit the number of risers in each flight and each landing…
- D3D16 Thresholds NSWThe threshold of a doorway must not incorporate a step or ramp at any point closer to the doorway than the width of the door leaf unless the doorway…
- D3D17 Barriers to prevent fallsA continuous barrier must be provided along the side of— a roof to which general access is provided; and a stairway or ramp; and a floor, corridor,…
- D3D18 Height of barriers NSWThe height of a barrier required by D3D17 must be not less than the following: For stairways or ramps with a gradient of 1:20 or steeper — 865 mm.…
- D3D19 Openings in barriersExcept where allowed by (2), openings in a required barrier must not allow a 125 mm sphere to pass through. (2) In a fire-isolated stairway,…
- D3D20 Barrier climbabilityA barrier required by D3D17, located on a floor more than 4 m above the surface beneath, must not incorporate horizontal or near horizontal elements…
- Table D3D21a Wire barrier construction – minimum required tension (N) for stainless steel horizontal wiresWire dia. (mm) | Lay | Wire spacing (mm) | Clear distance between posts (mm) 600 | 800 | 900 | 1000 | 1200 | 1500 | 1800 | 2000 | 2500 2.5 | 7x7 |…
- Table D3D21b Continuous wire barrier construction – minimum required tension (N) for vertical or near-vertical stainless steel wires where the maximum clear spacing between the rails is 900 mmWire dia. (mm) | Lay | Widest spacing between wires (mm) | Required tension (N) 2.5 | 7x19 | 80 | 145 100 | 310 110 | 610 2.5 | 7x7 | 80 | 130 100 |…
- Table D3D21c Wire barrier construction – maximum permissible deflection of each wire in mm when a 2 kg mass is suspended at mid-span for stainless steel wiresWire dia. (mm) | Wire spacing (mm) | Clear distance between posts (mm) 600 | 900 | 1200 | 1500 | 1800 | 2000 2.5 | 60 | 17 | 11 | 9 | 8 | 8 | 8 80 |…
- D3D21 Wire barriersWhere a required barrier is constructed of wire, it is deemed to meet the requirements of D3D19(1) if it is constructed in accordance with the…
- D3D22 HandrailsSubject to (2), handrails must— be located along at least one side of the ramp or flight; and be located along each side if the total width of the…
- D3D23 Fixed platforms, walkways, stairways and laddersA fixed platform, walkway, stairway, ladder and any going and riser, landing, handrail or barrier attached thereto may comply with AS 1657 in lieu…
- D3D24 Doorways and doors NSWA doorway in a resident use area of a Class 9c building must not be fitted with— a sliding fire door; or a sliding smoke door; or a revolving door;…
- D3D25 Swinging doorsA swinging door in a required exit or forming part of a required exit — must not encroach— at any part of its swing by more than 500 mm on the…
- D3D26 Operation of latch NSW VICA door in a required exit, forming part of a required exit or in the path of travel to a required exit must be readily openable without a key from…
- D3D27 Re-entry from fire-isolated exitsDoors of a fire-isolated exit must not be locked from the inside as follows: In a Class 2 building. In a Class 3 building. In a Class 6 building. In…
- D3D28 Signs on doorsA sign, to alert persons that the operation of certain doors must not be impaired, must be installed where it can readily be seen on, or adjacent…
- D3D29 Protection of openable windowsA window opening must be provided with protection, if the floor below the window is 2 m or more above the surface beneath in— a bedroom in a Class 2…
- D3D30 Timber stairways: ConcessionNotwithstanding D3D3(a), timber treads, risers, landings and associated supporting framework within a required fire-isolated stairway or…
- D3D31 Wayfinding signageBuildings with an effective height of more than 12 m or with more than 3 below ground storeys must be provided with stairway identification signs,…