Deemed-to-Satisfy Provision · NCC 2025 Volume One
F1D12 Roof coverings
A roof must be covered with—
roof tiles complying with AS 2049, fixed in accordance with AS 2050; or
metal sheet roofing complying with AS 1562.1; or
plastic sheet roofing designed and installed in accordance with AS 1562.3; or
terracotta, fibre-cement and timber slates and shingles designed and installed in accordance with AS 4597, except in cyclonic areas; or
an external waterproofing membrane complying with F1D7.
New in NCC 2025. No F1D12 in NCC 2022 Volume One; it may have moved or been renumbered.
Can't meet F1D12? A Performance Solution must meet the Performance Requirements it satisfies: F1P1. Start a Performance Solution →