F4D12 Accessible adult change facilities
Part F4 Sanitary and other facilities · NCC 2019: F2.9
(1) One unisex accessible adult change facility must be provided in an accessible part of a—
Class 6 building that is a shopping centre having a design occupancy of not less than 3,500 people, calculated on the basis of the floor area and containing a minimum of 2 sole-occupancy units; and
Class 9b sports venue or the like that—
has a design occupancy of not less than 35,000 spectators; or
contains a swimming pool that has a perimeter of not less than 70 m and that is required by D4D2 to be accessible; and
museum, art gallery or the like having a design occupancy of not less than 1,500 patrons; and
theatre or the like having a design occupancy of not less than 1,500 patrons; and
passenger use area of an airport terminal building within an airport that accepts domestic and/or international flights that are public transport services as defined in the Disability Standards for Accessible Public Transport 2002.
(2) Accessible adult change facilities required by (1)—
must be constructed in accordance with Specification 27; and
cannot be combined with another sanitary compartment.
(3) For the purposes of (1), design occupancy must be calculated in accordance with D2D18, but excluding any area that—
can only be accessed by staff, employees, contractors, maintenance personnel and the like; or
is subject to an exemption under D4D5.