F7V1 Sound transmission through floors [F7P1]
Part F7 Sound transmission and insulation · NCC 2019: FV5.1
Compliance with F7P1 to avoid the transmission of airborne and impact generated sound through floors is verified when it is measured in-situ that the separating floor has—
airborne: a weighted standardised level difference with spectrum adaptation term (DnT,w + Ctr) not less than 45 when determined under AS ISO 717.1; and
impact: a weighted standardised impact sound pressure level (LnT,w) not more than 62 when determined under AS ISO 717.2.
Changed since NCC 2022 (minor wording). See NCC 2022 Volume One F7V1, or show what changed.
Compliance with F7P1 to avoid the transmission of airborne and … (DnT,w + Ctr) not less than 45 when determined under AS/NZS AS ISO 717.1; and impact: a weighted standardised impact sound pressure level (LnT,w) not more than 62 when determined under AS ISO 717.2.
Removed words are struck through; added words are highlighted. Comparison of the text only.