Part J5 Building sealing
8 clauses · Open on NCC Online ↗
- J5D1 Deemed-to-Satisfy Provisions NSWWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements J1P1 to J1P4 are satisfied by complying with— J2D2; and J3D2 to J3D15; and…
- J5D2 Application of Part NSWThe Deemed-to-Satisfy Provisions of this Part apply to— elements forming the envelope of a Class 3, 5, 6, 7, 8 or 9 building; and the external…
- J5D3 Chimneys and fluesThe chimney or flue of an open solid-fuel burning appliance must be provided with a damper or flap that can be closed to seal the chimney or flue.
- J5D4 Roof lightsA roof light must be sealed, or capable of being sealed, with— an imperforate ceiling diffuser or the like installed at the ceiling or internal…
- J5D5 Windows and doorsA door, openable window or the like must be sealed. (2) The requirements of (1) do not apply to— a window complying with AS 2047; or a fire door or…
- J5D6 Exhaust fansAn exhaust fan must be fitted with a sealing device such as a self-closing damper or the like unless it is necessary for the fan to operate…
- J5D7 Construction of roofs, ceilings, walls and floorsCeilings, walls, floors and any opening such as a window frame, door frame, roof light frame, ventilation opening frame or the like must be…
- J5D8 Evaporative coolersAn evaporative cooler must be fitted with a self-closing damper or the like in climate zones 4, 5, 6, 7 and 8.