J5D4 Roof lights
Part J5 Building sealing · NCC 2019: J3.3
A roof light must be sealed, or capable of being sealed, with—
an imperforate ceiling diffuser or the like installed at the ceiling or internal lining level; or
a weatherproof seal; or
a shutter system readily operated either manually, mechanically or electronically by the occupant.
Changed since NCC 2022. See NCC 2022 Volume One J5D4, or show what changed.
(1) A roof light must be sealed, or capable of being sealed, when serving — a conditioned space; or a habitable room in climate zones 4, 5, 6, 7 or 8. (2) A roof light required by (1) to be sealed, or capable of being sealed, must be constructed with — an imperforate ceiling diffuser or the like installed … readily operated either manually, mechanically or electronically by the occupant.
Removed words are struck through; added words are highlighted. Comparison of the text only.