Deemed-to-Satisfy Provision · NCC 2025 Volume One

J5D4 Roof lights

Part J5 Building sealing · NCC 2019: J3.3

Open J5D4 on NCC Online ↗

A roof light must be sealed, or capable of being sealed, with—

an imperforate ceiling diffuser or the like installed at the ceiling or internal lining level; or

a weatherproof seal; or

a shutter system readily operated either manually, mechanically or electronically by the occupant.

Changed since NCC 2022. See NCC 2022 Volume One J5D4, or show what changed.

(1) A roof light must be sealed, or capable of being sealed, when serving — a conditioned space; or a habitable room in climate zones 4, 5, 6, 7 or 8. (2) A roof light required by (1) to be sealed, or capable of being sealed, must be constructed with — an imperforate ceiling diffuser or the like installed … readily operated either manually, mechanically or electronically by the occupant.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Can't meet J5D4? A Performance Solution must meet the Performance Requirements it satisfies: J1P1, J1P2, J1P3, J1P4. Start a Performance Solution →

Defined terms used