Part J5 Building sealing · NCC 2019: J3.1, NSW J(A)2.1
(1) The Deemed-to-Satisfy Provisions of this Part apply to—
elements forming the envelope of a Class 3, 5, 6, 7, 8 or 9 building; and
the external building fabric of a Class 4 part of a building.
(2) Notwithstanding (1), the Deemed-to-Satisfy Provisions of this Part do not apply to—
a building in climate zones 1, 2, 3 or 5 where the only means of air-conditioning is by using an evaporative cooler; or
a permanent building opening, in a space where a gas appliance is located, that is necessary for the safe operation of a gas appliance; or
a building or space where the mechanical ventilation required by Part F6 provides sufficient pressurisation to prevent infiltration.
Changed since NCC 2022. See NCC 2022 Volume One J5D2, or show what changed.
(1) The Deemed-to-Satisfy Provisions of this Part apply to — elements forming the envelope of a Class 2 3, 5, 6, 7, 8 or 9 building; and the external building fabric of a Class 4 part of a building. (2) Notwithstanding (1), the Deemed-to-Satisfy Provisions of this Part do not apply to 9 building, other than — a building in climate zones 1, 2, 3 and or 5 where the only means of air-conditioning is by using … required by Part F6 provides sufficient pressurisation to prevent infiltration.