South Australia variation · NCC 2025 Volume One
SA I3D15 Design and operation of exit signs
SA Part I3 Farm buildings and farm sheds · varies I3D15 Design and operation of exit signs
Delete clause I3D15 and insert SA I3D15 as follows:
In a farm building, each required exit sign provided under E4D5, SA I3D13 and SA I3D14 need not comply with E4D8 if—
the use of illuminated exit signs may adversely impact the behaviour or welfare of animals being kept in the building; and
non-illuminated exit signs are installed in accordance with the requirements of Appendix D of AS/NZS 2293.1 as for an externally illuminated exit sign, and clauses 5.6 and 5.8 of AS/NZS 2293.1.
New in NCC 2025. No SA I3D15 in NCC 2022 Volume One; it may have moved or been renumbered.