NCC 2025 Volume One
Specification 36 Material properties
15 clauses · Open on NCC Online ↗
- S36C1 ScopeThis Specification lists the thermal properties of some common construction materials.
- Table S36C2a Thermal conductivity of typical framing materialsDescription | Density (kg/m3) | Thermal conductivity (Wm-1K-1) Steel | 7850 | 47.5 Timber – kiln dried hardwood (across the grain) | 677 | 0.16…
- Table S36C2b Thermal conductivity of typical roof cladding materialsDescription | Density (kg/m3) | Thermal conductivity (Wm-1K-1) Aluminium sheeting | 2680 | 210 Concrete or terra cotta tiles | 1922 | 0.81 Steel…
- Table S36C2c Thermal conductivity of typical wall cladding materialsDescription | Density (kg/m3) | Thermal conductivity (Wm-1K-1) Aluminium sheeting | 2680 | 210 Autoclaved aerated concrete | 350 | 0.10 510 | 0.15…
- Table S36C2d Thermal conductivity of typical flooring materialsDescription | Density (kg/m3) | Thermal conductivity (Wm-1K-1) Carpet underlay | - | 0.04 Carpet | - | 0.05 Prestressed hollow core concrete planks…
- Table S36C2e Thermal conductivity of other materials not listed in Tables S36C2a to S36C2dDescription | Density (kg/m3) | Thermal conductivity (Wm-1K-1) Clay soil (10% moisture content) | 1300 | 0.6 PMMA (polymethylmethacrylate) | 1180 |…
- Table S36C2f Typical R-Values for air films: surfaces other than outdoor surfacesPosition of air film | Direction of heat flow | R-Value On a surface with a pitch of not more than 5° | Up | 0.11 Down | 0.16 On a surface with a…
- Table S36C2g Typical R-Values for air films: outdoor surfacesPosition of air film | Direction of heat flow | R-Value Any | Any | 0.03
- Table S36C2h Typical R-Values for airspaces: non-reflective non-ventilatedPosition of airspace | Direction of heat flow | R-Value In a roof with a pitch not more than 5° or cathedral ceiling with a 20 mm to 50 mm thick…
- Table S36C2i Typical R-Values for airspaces: reflective non-ventilatedPosition of airspace | Direction of heat flow | R-Value In a wall with an inner reflective surface of 0.05 emittance and a 20 mm to 100 mm airspace…
- Table S36C2j Typical R-Values for airspaces: non-reflective ventilatedPosition of airspace | Direction of heat flow | R-Value In a roof airspace greater than 300 mm thick or with a horizontal ceiling and a pitch more…
- Table S36C2k Typical R-Values for roof spaces with a reflective surface: Roof space > 300 mm thick or pitched roof with a horizontal ceilingDirection of heat flow | R-Value of reflective airspace Ventilated roof space | Non-ventilated roof space Up | 0.34 | 0.56 Down | 1.36 | 1.09 Table…
- Table S36C2l Typical R-Values for non-ventilated roof spaces with a reflective surface: Flat, skillion or pitched roof (≤5°) with horizontal ceiling, roof space not more than 300 mm thickEmittance of airspace bounding surfaces | Thickness of roof space | Direction of heat flow | R-Value of reflective airspace Surface 1 emittance 0.9,…
- Table S36C2m Typical R-Values for non-ventilated roof spaces with a reflective surface: Pitched roof with cathedral ceiling, roof space not more than 300 mm thickEmittance of airspace bounding surfaces | Thickness of roof space | Direction of heat flow | R-Value of reflective airspace 15° to not more than 25°…
- S36C2 Construction Deemed-to-SatisfyTables S36C2a, S36C2b, S36C2c, S36C2d and S36C2e list the thermal conductivity considered to be achieved by some common construction materials. (2)…