Table · NCC 2025 Volume One

Table D3D14 Riser and going dimensions

Part D3 Construction of exits

Open Table D3D14 on NCC Online ↗
Stairway locationRiser (R)Going (G)Note 3Quantity (2R + G)
MaxMinMaxMinMaxMin
Public190115355250700550
Private Note 1190115355240700550

Table Notes

Private stairways are—

stairways in a sole-occupancy unit in a Class 2 building or Class 4 part of a building; and

in any building, stairways which are not part of a required exit and to which the public do not normally have access.

Going and riser dimensions must be measured in accordance with Figure D3D14.

The going in tapered treads (except winders in lieu of a quarter or half landing) in a curved or spiral stairway is measured—

270 mm in from the outer side of the unobstructed width of the stairway if the stairway is less than 1 m wide (applicable to a non-required stairway only); and

270 mm from each side of the unobstructed width of the stairway if the stairway is 1 m wide or more.

Table for D3D14 Goings and risers

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table D3D14.

Clauses referred to

Defined terms used