Table · NCC 2025 Volume One
Table D3D21b Continuous wire barrier construction – minimum required tension (N) for vertical or near-vertical stainless steel wires where the maximum clear spacing between the rails is 900 mm
| Wire dia. (mm) | Lay | Widest spacing between wires (mm) | Required tension (N) |
|---|---|---|---|
| 2.5 | 7x19 | 80 | 145 |
| 100 | 310 | ||
| 110 | 610 | ||
| 2.5 | 7x7 | 80 | 130 |
| 100 | 280 | ||
| 110 | 500 |
Table Notes
Lay = number of strands by the number of individual wires in each strand. For example a lay of 7x19 consists of 7 strands with 19 individual wires in each strand.
Vertical wires require two pulley blocks to each 180° change of direction in the wire.
Near vertical wires may only require one pulley block for each change of direction.
Tension measured with a strain indicator.
The table only includes 7x7 and 7x19 wires due to other wires not having sufficient flexibility to make the necessary turns.
Table for D3D21 Wire barriers
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table D3D21b.