Table · NCC 2025 Volume One

Table F4D4i Sanitary facilities in Class 9b buildings – single auditorium theatres and cinemas

Part F4 Sanitary and other facilities

Open Table F4D4i on NCC Online ↗
User groupFacility typeDesign occupancyNumber
Male patronsCloset pans1 - 500
51 - 2501
251 - 5002
>500Add 1 per 500
Urinals1 - 500
51 - 1001
>100Add 1 per 100
Washbasins1 - 500
51 - 1501
>150Add 1 per 150
Female patronsCloset pans1 - 500
51 - 754
76 - 1105
111 - 1706
171 - 2307
231 - 2509
>250Add 1 per 60
Washbasins1 - 500
51 - 1501
>150Add 1 per 150

Table for F4D4 Facilities in Class 3 to 9 buildings

Changed since NCC 2022. See NCC 2022 Volume One Table F4D4i, or show what changed.

User group | Facility type | Design occupancy | Number … Closet pans | 1 - 50 | 0 51 - 75 | 4 76 - 110 | 3 5 111 - 170 | 4 6 171 - 230 | 5 7 231 - 250 | 6 9 >250 | Add 1 per 80 60 Washbasins | 1 - 50 | 0 51 - 150 | 1 >150 | Add 1 per 150

Removed words are struck through; added words are highlighted. Comparison of the text only.