Table · NCC 2025 Volume One
Table F4D4i Sanitary facilities in Class 9b buildings – single auditorium theatres and cinemas
Part F4 Sanitary and other facilities
| User group | Facility type | Design occupancy | Number |
|---|---|---|---|
| Male patrons | Closet pans | 1 - 50 | 0 |
| 51 - 250 | 1 | ||
| 251 - 500 | 2 | ||
| >500 | Add 1 per 500 | ||
| Urinals | 1 - 50 | 0 | |
| 51 - 100 | 1 | ||
| >100 | Add 1 per 100 | ||
| Washbasins | 1 - 50 | 0 | |
| 51 - 150 | 1 | ||
| >150 | Add 1 per 150 | ||
| Female patrons | Closet pans | 1 - 50 | 0 |
| 51 - 75 | 4 | ||
| 76 - 110 | 5 | ||
| 111 - 170 | 6 | ||
| 171 - 230 | 7 | ||
| 231 - 250 | 9 | ||
| >250 | Add 1 per 60 | ||
| Washbasins | 1 - 50 | 0 | |
| 51 - 150 | 1 | ||
| >150 | Add 1 per 150 |
Table for F4D4 Facilities in Class 3 to 9 buildings
Changed since NCC 2022. See NCC 2022 Volume One Table F4D4i, or show what changed.
User group | Facility type | Design occupancy | Number … Closet pans | 1 - 50 | 0 51 - 75 | 4 76 - 110 | 3 5 111 - 170 | 4 6 171 - 230 | 5 7 231 - 250 | 6 9 >250 | Add 1 per 80 60 Washbasins | 1 - 50 | 0 51 - 150 | 1 >150 | Add 1 per 150
Removed words are struck through; added words are highlighted. Comparison of the text only.