Tasmania variation · NCC 2025 Volume One

TAS I4D5 Drains and pipes

TAS Part I4 Food premises

Open on NCC Online ↗

Delete clause I4D5 and insert TAS I4D5 as follows:

Premises satisfy TAS I4P4 where—

a grease trap, an overflow (relief) gully or an untrapped opening connected directly with a drain or sewer, is not installed in a room used for preparation, processing, packing or storing of food for sale; and

as far as is practicable, service pipes are concealed beneath the surface of walls, floors or ceilings, or are fixed clear of the wall, floor or ceiling, at such distance as to facilitate cleaning.

Changed since NCC 2022. See NCC 2022 Volume One TAS I4D5, or show what changed.

Delete clause I4D5 and insert TAS I4D5 as follows: Premises satisfy TAS I4P4 where — a grease trap, an … floor or ceiling, at such distance as to facilitate cleaning.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Other states and territories