Table · ABCB Housing Provisions 2022

Table 4.2.20b Localised thickening under concentrated load — tiled floor and tiled roof — roof load area = maximum 9 m2

Part 4.2 Footings, slabs and associated elements

Open Table 4.2.20b on NCC Online ↗
Localised thickeningMaximum floor load area (m2)
41016
Square thickening size (mm)650 x 650800 x 800950 x 950
Thickening depth (mm)350400450

Table Notes

Load accounted for includes 0.98 kPa permanent tiled floor, 0.85 kPa permanent tiled roof, 1.16 kN/m permanent wall, permanent member self-weight, 1.5 kPa or 1.1 kN imposed floor and 0.25 kPa imposed roof.

Load combinations included are G + 0.5Q for ULS.

Minimum bearing pressure is 1000 kPa for pad footings.

The length of wall allowed for is equal to the square root of the floor area.

Table for 4.2.20 Concentrated loads

Changed in NCC 2025 (minor wording). See ABCB Housing Provisions 2025 Table 4.2.20b, or show what changed.

Localised thickening | Maximum floor load area (m2) 4 | … are G + 0.5Q for ULS. Minimum bearing pressure is 1000 100 kPa for pad footings. The length of wall allowed for is equal to the square root of the floor area.