Deemed-to-Satisfy Provision · NCC 2022 Volume One

D2D18 Number of persons accommodated

Part D2 Provision for escape · NCC 2019: D1.13

Open D2D18 on NCC Online ↗

For the purposes of the Deemed-to-Satisfy Provisions, the number of persons accommodated in a storey, room or mezzanine must be determined with consideration to the purpose for which it is used and the layout of the floor area by—

calculating the sum of the numbers obtained by dividing the floor area of each part of the storey by the number of square metres per person listed in Table D2D18 according to the use of that part, excluding spaces set aside for—

lifts, stairways, ramps and escalators, corridors, hallways, lobbies and the like; and

service ducts and the like, sanitary compartments or other ancillary uses; or

reference to the seating capacity in an assembly building or room; or

any other suitable means of assessing its capacity.

Table D2D18 Area per person according to use

Type of use

Area per person

Art gallery, exhibition area, museum

4 m2

Bar — standing

0.5m2

Bar — other

1 m2

Board room

2 m2

Boarding house

15 m2

Cafe, church, dining room

1 m2

Carpark

30 m2

Computer room

25 m2

Court room — judicial area

10 m2

Court room — public seating

1 m2

Dance floor

0.5 m2

Dormitory

5 m2

Early childhood centre

4 m2

Factory — machine shop, fitting shop or like place for cutting, grading, finishing or fitting of metals or glass, except in the fabrication of structural steelwork or manufacture of vehicles or bulky products

5 m2

Factory — areas used for fabrication and processing other than a machine shop, fitting shop or the like.

50 m2

Factory — a space in which the layout and natural use of fixed plant or equipment determines the number of persons who will occupy the space during working hours

Area per person determined by the use of the plant or equipment

Gymnasium

3 m2

Hostel, hotel, motel, guest house

15 m2

Indoor sports stadium—arena

10 m2

Kiosk

1 m2

Kitchen, laboratory, laundry

10 m2

Library — reading space

2 m2

Library — storage space

30 m2

Office, including one for typewriting or document copying

10 m2

Patient care areas

10 m2

Plant room — ventilation, electrical or other service units

30 m2

Plant room — boilers or power plant

50 m2

Reading room

2 m2

Restaurant

1 m2

School — general classroom

2 m2

School — multi-purpose hall

1 m2

School — staff room

10 m2

School — trade and practical area — primary

4 m2

School — trade and practical area — secondary

As for workshop

Shop — space for sale of goods — at a level entered direct from the open air or any lower level

3 m2

Shop — space for sale of goods — all other levels

5 m2

Showroom — display area, covered mall or arcade

5 m2

Skating rink, based on rink area

1.5 m2

Spectator stand, audience viewing area — standing viewing area

0.3 m2

Spectator stand, audience viewing area — removable seating

1 m2

Spectator stand, audience viewing area — fixed seating

Per number of seats

Spectator stand, audience viewing area — bench seating

450 mm/person

Storage space

30 m2

Swimming pool, based on pool area

1.5 m2

Switch room, transformer room

30 m2

Telephone exchange — private

30 m2

Theatre and public hall

1 m2

Theatre dressing room

4 m2

Transport terminal

2 m2

Workshop — for maintenance staff

30 m2

Workshop — for manufacturing processes

As for factory

Table Notes

Bar standing is an area used by the standing patrons and extends not less than 1.5 m wide from the outside edge of the bar top for the length of the serving area of the bar.

Tables

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One D2D18.
Can't meet D2D18? A Performance Solution must meet the Performance Requirements it satisfies: D1P1, D1P2, D1P3, D1P4, D1P5, D1P6, D1P8, D1P9. Start a Performance Solution →

Defined terms used