NCC 2022 Volume One
Part D2 Provision for escape
20 clauses · Open on NCC Online ↗
- D2D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 and D1P9 are satisfied by complying with— D2D2 to D2D23,…
- D2D2 Application of PartThe Deemed-to-Satisfy Provisions of this Part do not apply to the internal parts of a sole-occupancy unit in a Class 2 or 3 building or a Class 4…
- D2D3 Number of exits required NSW SAAll buildings — Every building must have at least one exit from each storey. (2) Class 2 to 8 buildings — In addition to any horizontal exit, not…
- D2D4 When fire-isolated stairways and ramps are required SAClass 2 and 3 buildings — The following applies: Subject to (b), every stairway or ramp serving as a required exit must be fire-isolated unless it…
- D2D5 Exit travel distances SA VICClass 2 and 3 buildings — The entrance doorway of any sole-occupancy unit must be not more than— 6 m from an exit or from a point from which travel…
- D2D6 Distance between alternative exits SAExits that are required as alternative means of egress must be— distributed as uniformly as practicable within or around the storey served and in…
- D2D7 Height of exits, paths of travel to exits and doorwaysIn a required exit or path of travel to an exit the unobstructed height throughout must be not less than 2 m, except the unobstructed height of any…
- D2D8 Width of exits and paths of travel to exits NSWThe unobstructed width of each required exit or path of travel to an exit, except for ladders provided in accordance with D2D21, D3D23 or I3D5, and…
- D2D9 Width of doorways in exits or paths of travel to exits NSW VICIn a required exit or path of travel to an exit, the unobstructed width of a doorway must be not less than— in patient care areas through which…
- D2D11 Determination and measurement of exits and paths of travel to exitsFor the purposes of D2D7 to D2D10 the following apply: The required width of a stairway or ramp in a required exit or path of travel to an exit…
- D2D13 External stairways or ramps in lieu of fire-isolated exitsAn external stairway or ramp may serve as a required exit in lieu of a fire-isolated exit serving a storey below an effective height of 25 m, if the…
- D2D14 Travel by non-fire-isolated stairways or ramps SAA non-fire-isolated stairway or non-fire-isolated ramp serving as a required exit must provide a continuous means of travel by its own flights and…
- D2D15 Discharge from exits NSWAn exit must not be blocked at the point of discharge and where necessary, suitable barriers must be provided to prevent vehicles from blocking the…
- D2D16 Horizontal exitsHorizontal exits must not be counted as required exits— between sole-occupancy units; or in a Class 9b building used as an early childhood centre,…
- Table D2D18 Area per person according to useType of use | Area per person Art gallery, exhibition area, museum | 4 m2 Bar — standing | 0.5m2 Bar — other | 1 m2 Board room | 2 m2 Boarding house…
- D2D18 Number of persons accommodatedFor the purposes of the Deemed-to-Satisfy Provisions, the number of persons accommodated in a storey, room or mezzanine must be determined with…
- D2D19 Measurement of distancesThe nearest part of an exit means in the case of— a fire-isolated stairway, fire-isolated passageway, or fire-isolated ramp, the nearest part of the…
- D2D20 Method of measurementThe following rules apply: In the case of a room that is not a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building, the…
- D2D21 Plant rooms, lift machine rooms and electricity network substations: Concession SAA ladder may be used in lieu of a stairway to provide egress from— a plant room with a floor area of not more than 100 m2; or all but one point of…
- D2D23 Egress from primary schoolsEvery part of a Class 9b primary school must be wholly within a storey that provides direct egress to a road or open space. (2) The requirements of…