Deemed-to-Satisfy Provision · NCC 2022 Volume One
D2D19 Measurement of distances
Part D2 Provision for escape · NCC 2019: D1.14
The nearest part of an exit means in the case of—
a fire-isolated stairway, fire-isolated passageway, or fire-isolated ramp, the nearest part of the doorway providing access to them; and
a non-fire-isolated stairway, the nearest part of the nearest riser; and
a non-fire-isolated ramp, the nearest part of the junction of the floor of the ramp and the floor of the storey; and
a doorway opening to a road or open space, the nearest part of the doorway; and
a horizontal exit, the nearest part of the doorway.
Same wording in NCC 2025 Volume One. See NCC 2025 Volume One D2D19.
Can't meet D2D19? A Performance Solution must meet the Performance Requirements it satisfies: D1P1, D1P2, D1P3, D1P4, D1P5, D1P6, D1P8, D1P9. Start a Performance Solution →